Fluke 117 Electrical Digital Multimeter True RMS 600V
The Fluke 117 True RMS digital multimeter is the perfect troubleshooting tool for "go/no go" non-contact voltage detection. It has a selectable low-impedance mode to prevent false readings from ghost voltage. Designed specifically for electricians.
FEATURES
> Non-contact voltage detection
> AutoVolt, automatic AC/DC voltage selection
> Safety-rated CAT III 600 V
> Maximum resolution is 1 milliamp
> True-RMS for accurate measurements on non-linear loads
> Measures 20A (30 seconds momentary; 10 A continuous)
> Measures resistance, continuity, frequency, capacitance, and min/max/average
> Large white LED backlight to work in poorly lit areas
> Provides Min/Max/Average with elapsed time to record signal fluctuations
SPECIFICATIONS
Max voltage 600V
Safety IEC 61010-2-033 CAT III 600 V
Digital display 6,000 count, updates 4 times per second
Bar graph 33 segments, updates 32 times per second
Typical battery life 400 hours without backlight
ACCURACY SPECIFICATIONS
DC millivolts range/resolution 600.0 mV / 0.1 mV
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
DC volts range/resolution 6.000 V / 0.001 V, 60.00 V / 0.01 V, 600.00 V / 0.1 V
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
Auto volts range/resolution 600.0 V / 0.1 V
Accuracy 2.0% + 3 (DC, 45 Hz to 500 Hz), 4.0% + 3 (500 Hz to 1 kHz)
AC millivolts True RMS range/resolution 600.0 mV / 0.1 mV
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz), 2.0% + 3 (500 Hz to 1 kHz)
AC volts True RMS range/resolution 6.000 V / 0.001, V60.00 V / 0.01, V600.0 V / 0.1 V
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz), 2.0% + 3 (500 Hz to 1 kHz)
Continuity range/resolution 600 ? / 1 ?
Accuracy Beeper on < 20 ?, off > 250 ? detects opens or shorts of 500 ?s or longer
Ohms
Range/resolution 600.0 ? / 0.1 ?, 6.000 k? / 0.001 k?, 60.00 k? / 0.01 k?, 600.0 k? / 0.1 k?, 6.000 M? / 0.001 M?
Accuracy 0.9% + 1
Range/resolution 40.00 M? / 0.01 M?
Accuracy 5% + 2
Diode test
Range/resolution 2.00 V / 0.001 V
Accuracy 0.9% + 2
Capacitance
Range/resolution 1000 nF / 1 nF, 10.00 ?F / 0.01 ?F, 100.0 ?F / 0.1 ?F, 9999 ?F / 1 ?F, 100 ?F to 1000 ?F
Accuracy 1.9% + 2
Range/resolution > 1000 ?F
Accuracy 5% + 20%
Lo-Z capacitance Range 1 nF to 500 ?F
Accuracy 10% + 2 typical
AC amps True RMS (45 Hz to 500 Hz)
Range/resolution 6.000 A / 0.001 A, 10.00 A / 0.01 A
Accuracy 1.5% + 3 20 A continuous overload for 30 seconds max
DC amps Range/resolution 6.000 A / 0.001 A, 10.00 A / 0.01 A
Accuracy 1.0% + 3 20 A continuous overload for 30 seconds max
Hz (V or A input)²
Range/resolution 99.99 Hz / 0.01 Hz, 999.9 Hz / 0.1 Hz, 9.999 kHz / 0.001 Hz, 50.00 kHz / 0.01 Hz
Accuracy 0.1% + 2
Battery powered 9 volt alkaline 6LR61
Size 167H x 84W x 46D mm
Weight 550g
WHAT YOU GET
Fluke 117 Digital Multimeter
Test leads with 4mm tips and protective caps
Holster
Battery 9V
User manual