The Fluke 114 True RMS digital multimeter is the perfect troubleshooting tool for "go/no go" testing. You can use the LoZ function to identify so-called ghost voltage and prevent false readings. Ideal for electricians and contractors.
FEATURES
> Compact ergonomic design for one-handed operation
> AutoVolt automatic AC/DC voltage selection
> Safety-rated CAT III 600 V
> Measures AC/DC voltage, resistance, and continuity
> Large white LED backlight for working in poorly lit areas
> Provides Min/Max/Average with elapsed time to record signal fluctuations
> Includes low input impedance to help prevent false readings due to ghost voltage
SPECIFICATIONS
Max voltage 600V
Safety IEC 61010-2-033 CAT III 600 V
Digital display 6,000 count, updates 4 times per second
Bar graph 33 segments, updates 32 times per second
Typical battery life 400 hours without backlight
ACCURACY SPECIFICATIONS
DC millivolts range/resolution 600.0 mV / 0.1 mV
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
DC volts range/resolution 6.000 V / 0.001, V60.00 V / 0.01, V600.00 V / 0.1 V
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
Auto volts range/resolution 600.0 V / 0.1 V
Accuracy 2.0% + 3 (DC, 45 Hz to 500 Hz), 4.0% + 3 (500 Hz to 1 kHz)
AC millivolts True RMS range/resolution 600.0 mV / 0.1 mV
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz), 2.0% + 3 (500 Hz to 1 kHz)
AC volts True RMS range/resolution 6.000 V / 0.001, V60.00 V / 0.01, V600.0 V / 0.1 V
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz), 2.0% + 3 (500 Hz to 1 kHz)
Continuity range/resolution 600 Ω / 1 Ω
Accuracy Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer.
Ohms
Range/resolution 600.0 Ω / 0.1 Ω, 6.000 kΩ / 0.001 kΩ, 60.00 kΩ / 0.01 kΩ, 600.0 kΩ / 0.1 kΩ, 6.000 MΩ / 0.001 MΩ
Accuracy 0.9% + 1
Range/resolution 40.00 MΩ / 0.01 MΩ
Accuracy 5% + 2
Battery powered 9 volt alkaline 6LR61
Size 167H x 84W x 46D mm
Weight 550g
WHAT YOU GET
Fluke 114 Digital Multimeter
Test leads
Holster
Battery
User manual
No reviews found